corezon:property key='company.name' />
shopping cart  |  order status  |  help  |  my account  |  sign in 
search  
  advanced search 
800-684-4651 sales@tesales.com
Amplifiers / Attenuators
Analyzers
BK Precision Accessories
Calibrators
Data Acquisition
Fiber Optical Equipment
Frequency Counters
IC Testers / Programmers
Meters
Miscellaneous Equipment
Network/Telecomm Equipment
Oscilloscopes
Power Supplies
Probes & Supplies
Pulse/Function/Abitrary Generators
Signal Generators
TV/Video/Satellite Test Equipment
Get the Store Newsletter
  

We Accept: 

 

Electronic Payments

Home Page >Oscilloscopes > Used Scopes > LeCroy LC584AXL 1 GHz, 4 Channel, Used Digitial Oscilloscope (LC584AXL )

LC584AXL


LeCroy LC584AXL 1 GHz, 4 Channel, Used Digitial Oscilloscope

Price : $5,995.00
Item# LC584AXL
Mfg. Part# LC584AXL
Condition Used


or

Product Overview

LeCroy LC584AXL Oscilloscope, Digital: 1GHz,8GSa/s,4ch (Stand alone)

The LeCroy LC584AXL oscilloscope is a graph-displaying device – it draws a graph of an electrical signal. In most applications, the graph shows how signals change over time: the vertical (Y) axis represents voltage and the horizontal (X) axis represents time. The intensity or brightness of the display is sometimes called the Z axis.

The LeCroy LC584AXL oscilloscope’s simple graph can tell you many things about a signal, such as: the time and voltage values of a signal, the frequency of an oscillating signal, the “moving parts” of a circuit represented by the signal, the frequency with which a particular portion of the signal is occurring relative to, other portions, whether or not a malfunctioning component is distorting the signal, how much of a signal is direct current (DC) or alternating current (AC) and how much of the signal is noise and whether the noise is changing with time.


Technical Specifications

Acquisition System


BANDWIDTH (-3 DB):

LC564/LC584 @ 50 Ohms: DC to 1 GHz


LC684D @ 50 Ohms: DC to 1.5 GHz


@ 1 MOhms: Bandwidth dependent on probe used.


SENSITIVITY:

LC564/LC584/LC684D: 2 mV/div to 1 V/div,50 Ohms, fully variable.


LC564/LC584: 2 mV/div to 10 V/div, 1 MOhms, fully variable.


LC684D: 2 mV/div to 2 V/div, 1 MOhms, fully variable.


SCALE FACTORS: Choice of over 12 probe attenuation factors selectable via front panel menus.


OFFSET RANGE:

±20 V across the whole sensitivity range when using the AP020/AP022 active probe.


LC684D:

2.00 ­ 4.99 mV/div: ±400 mV


5.00 ­ 99 mV/div (50 Ohms only): ±1 V


0.1 ­ 1.0 V/div (50 Ohms only): ±10 V


5.0 ­ 100 mV/div (1 MOhms only): ±1 V


102 mV ­ 2.0 V/div (1 MOhms only): ±20 V


LC564/LC584:

1.0 ­ 10.0 V/div (1 MOhms only): ±100 V


2.00 ­ 4.99 mV/div: ±400 mV


0.1 ­ 0.99 V/div: ±10 V


DC ACCURACY:

LC684D: Typically ±(2% full scale + 1% offset setting).


LC584A: Typically ±(1% full scale + 1% offset setting).


VERTICAL RESOLUTION: 8 bits


BANDWIDTH LIMITER: 25 MHz and 200 MHz typical


INPUT COUPLING: AC (>10 Hz typ.), DC, GND


INPUT IMPEDANCE: 10 MOhms//11 pF typical (using PP005 probe), or 50 Ohms ±1.25%.


MAX INPUT VOLTAGE:

50 Ohms: ±5 V DC (500 mW) or 5 V RMS



LC564/LC584 SERIES: 1 MOhms: 400 V (DC + peak AC ¾10 kHz)



LC684D SERIES:1 MOhms: 100 V (DC + peak AC @ 10 kHz)


Acquisition Modes


RANDOM INTERLEAVED SAMPLING (RIS): 25 GS/s. For repetitive signals from 200 ps/div to
1 µs/div.


SINGLE SHOT: For transient and repetitive signals from 0.5 ns/div (1 Ch), 1 ns/div (2 Ch), 2 ns/div (4 Ch).


SEQUENCE: Stores multiple events -- each of them time stamped (1 ns resolution) -- in segmented acquisition memories.


SEQUENCE MODE DEAD TIME: Typically 30 µs


NUMBER OF SEGMENTS AVAILABLE:

LC564/LC584A,LC684D 2 ­ 1000


LC584AM/AL/AXL 2 ­ 2000


LC684DM/DL/DXL 2 ­ 2000


Timebase System


TIMEBASES: Main and up to 4 Zoom Traces.


TIME/DIV RANGE:

500 ps/div (at 8 GS/s), 1 ns/div (at 4 GS/s),
2 ns/div (at 2 GS/s) to 1,000 s/div


CLOCK ACCURACY: 10 ppm


INTERPOLATOR RESOLUTION:

5 ps on LC684 Series


10 ps on LC584/564 Series


ROLL MODE IN NORMAL TRIGGER MODE: 500 ms/div to 1,000 s/div


EXTERNAL CLOCK: Optional (CKTRIG) up to 500 MHz rear-panel fixed-frequency clock input (<20 ns rise/falltime).


EXTERNAL REFERENCE: Optional (CKTRIG) 10 MHz rear-panel input.


Triggering System


MODES: Normal, Auto, Single, and Stop


SOURCES: CH1, CH2, CH3, CH4, Line, Ext, Ext/5, Slope. Level and Coupling are unique for each source.


SLOPE: Positive, Negative, Bi-Slope (Window in & out).


COUPLING: DC, AC (>10 Hz), HF (175 MHz to >1 GHz), LFREJ (>50 kHz), HFREJ (<100 MHz)


PRE-TRIGGER RECORDING: 0 to 100% of full scale (adjustable in 1% increments).


POST-TRIGGER DELAY: 0 to 10,000 divisions
(adjustable in 0.1 div. increments).


HOLDOFF BY TIME: 2 ns to 20 s


HOLDOFF BY EVENTS: 1 to 99,999,999


INTERNAL TRIGGER RANGE: ±5 div


MAXIMUM TRIGGER FREQUENCY: 1 GHz (DC, AC), >1 GHz (HF) on LC584/564, >1.5 GHz (HF) on LC684


EXT TRIGGER MAX. INPUT: 50 Ohms ±1%: ±5 V DC (500 mW) or 5 V RMS.

LC564/LC584 SERIES: 400 V (DC+ peak AC ¾10 kHz). 10 M Ohms // 11 pF at probe tip (PP005).



L684 SERIES: 100 V (DC+ peak AC ¾10 kHz). 10 M Ohms // 11 pF at probe tip (PP005).


EXT TRIGGER RANGE: ±0.5 V (±2.5 V with Ext/5)


MAXIMUM EXTERNAL TRIGGER FREQUENCY: 750 MHz when using 50 Ohms coupling.


TRIGGER OUTPUT:

Optional ECL rear panel output (option CKTRIG). The calibrator output can provide a trigger status signal or a Pass/Fail test output.


Autosetup


Automatically sets sensitivity, vertical offset and timebase on all display channels.


AUTOSETUP TIME: Approximately three seconds


VERTICAL FIND: Automatically sets sensitivity and offset for selected channel.

Probes


MODEL: One PP005 probe supplied per channel.


OPTIONAL PROBES: 1 GHz active probe (AP020); 2.5 GHz active probe (AP022);
1 GHz active differential probe (AP034).


PROBE CALIBRATION: Max 1 V into 1 MOhms, 500 mV into 50 Ohms, frequency and amplitude programmable, pulse, or square wave selectable; rise and fall time 1 ns typical. Alternatively, the calibrator output can provide a trigger output or a Pass/Fail test output.

Acquisition System Configuration

Bandwidth Maximum Record Length

Active

Maximum

1.5 GHz

 

LC684D

LC684DM

LC684DL

LC684DXL

Channels

Sample Rate

1 GHz

LC564A

LC584A

LC584AM

LC584AL

LC584AXL

 

4

2 GS/s

 

100 k

100 k

 

500 k

 

2 M

 

4 M

 

2

4 GS/s

 

250k

 

250 k

 

1 M

 

4 M

 

8 M

 

1

8 GS/s

 

 

 

 

500 k

 

2 M

 

8 M

 

16 M

 

Technical Specifications

SMART Trigger Types

Name Description


Basic Triggers


Edge/Slope/Window/Line Triggers when signal meets slope and level condition.


SMART Triggers


State or Edge Qualified

Triggers on any input source only if a defined state or edge occurred on another input source.

Delay between sources is selectable by time or events.

Dropout

Trigger if signal drops out for longer than selected time between 2 ns and 20 s.

Pattern

Logic combination of 5 inputs (4 channels and external trigger input);

Each source can be high, low, or don't care. Trigger at start or end of the pattern.

TV-Video Triggers odd or even fields for NTSC, PAL SECAM, or nonstandard video (up to 1500 lines).


SMART Triggers with Exclusion Technology


Signal or Pattern Width Triggers on glitches or on pulse widths selectable from 600 ps to 20 s or on intermittent faults.


Signal or Pattern Interval Triggers on intervals selectable between 2 ns and 20 s.


Slew Rate

Trigger on edge rates; select limits for dV, dt, and slope. Select dt from 600 ps to 20 s.

Runt

Positive or negative runts defined by two voltage limits and two time limits selectable between 600 ps and 20 ns.

Technical Specifications

TYPE:

LC584A Series: Color 10" Raster Scan CRT,
0.26 mm dot pitch.


LC684D Series: Color 10.4" TFT LCD


RESOLUTION: VGA (640 x 480 pixels)


DISPLAY AREA:

LC584A Series: 170 mm x 125 mm


LC684D Series: 212 mm x 160 mm


CONTROLS: Rear-panel presets for position, brightness and contrast. Menu controls for brightness and color selection.


GRID STYLES: Single, Dual, Quad, Octal, XY, Single+XY, Dual+XY, and Full Screen -- an enlarged view of each grid style.


GRATICULES: Internally generated; separate intensity control for grids and waveforms. Selectable blending of grid with displayed traces.


WAVEFORM STYLE: Dot-join with optional bold sample point highlight or dots-only.


PERSISTENCE MODES: Color-graded persistence and Analog Persistence, infinite or variable with decay over time. In color-graded persistence, a color spectrum from red through violet is used to map signal intensity. With Analog Persistence, the brightness level of a single color denotes signal intensity. Each trace's persistence data is stored in 64k levels.


TRACE DISPLAY: Opaque or transparent mode, with overlap management.


NUMBER OF TRACES: 8 (supports a mix of channels, memories or math functions).


REAL-TIME CLOCK: Date, hours, minutes, seconds.


EXTERNAL MONITOR: Rear panel 15-pin socket for external VGA compatible monitor.


VERTICAL ZOOM: Up to 5x vertical expansion (50x with averaging, up to 40 µV/div sensitivity).


HORIZONTAL ZOOM: Waveforms can be expanded to 0.4 points/division.


AUTO SCROLL: Use Auto Scroll to automatically "PLAY" the captured signal to identify anomalies quickly and easily. With a selectable zoom expansion and scrolling speed, you can set up Auto Scroll to match your signal viewing needs. The scrolling speed can be adjusted during the scan to focus on the more interesting characteristics of the signal.

"REVERSE" enables you to quickly review any part of the signal.


Technical Specifications

Rapid Signal Processing


MICROPROCESSOR:

LC584A/LC684D, LC584AM/LC684DM, LC584AL/LC684DL: 96 MHz PowerPC 603e


LC584AXL/LC684DXL: 192 MHz PowerPC 603e


System Memory Configurations
MODEL SYSTEM RAM
LC564A/LC584A/LC684D 16 Mbytes
LC584AM/LC684DM 16 Mbytes
LC584AL/LC684DL 64 Mbytes
LC584AXL/LC684DXL 64 Mbytes

VIDEO MEMORY: 1 Mbyte


PERSISTENCE DATA MAP MEMORY: 16 bits per displayed pixel (64k levels).


Waveform Processing


Up to four processing functions may be performed simultaneously. Functions available are: Add, Subtract, Multiply, Divide, Negate, Identity, Summation Averaging, Sine x/x, Integral, Derivative, Square Root, Ratio, Absolute Value, and the advanced functions listed below.


AVERAGE: Up to 106 averages possible.


EXTREMA: Roof, Floor, or Envelope values from
1 to 106 sweeps.


ERES: Low-Pass digital filters provide up to 11-bit vertical resolution. Sampled data is always available, even when a trace is turned off.


FFT: Spectral analysis with five windowing
functions (Rectangular, Von Hann, Hamming, Flat Top, and Blackman-Harris) and FFT averaging.


STATISTICAL DIAGNOSTICS: The Parameter Analysis package permits in-depth diagnostics on waveform parameters. Live histogramming and trending of any waveform parameter measurement is possible. The histogram can be autoscaled to display the center and width of the distribution. This package is standard on the LC684 and LC584 series and optional on the LC564A.

Note: Any of the above processes can be invoked without losing the data.


 Internal Memory


WAVEFORM MEMORY: Up to four 16-bit memories (M1, M2, M3, M4).


ZOOM & MATH MEMORY: Up to four 16-bit Waveform Processing memories (A,B,C,D) whose length corresponds to the length of the channel acquisition memory.


SETUP MEMORY: Four non-volatile memories. The floppy drive and optional cards or disks may also be used for high-capacity waveform and setup storage.


Cursor Measurements


CURSOR MEASUREMENTS
TYPE SYMBOL FROM TO
Relative time first point on waveform any other point on waveform
Relative voltage select voltage level any other voltage level
Absolute time time and voltage relative to ground and trigger
Absolute voltage voltage ground

Automated Measurements


The following parametric measurements are available, together with their Average, Highest, Lowest values and Standard Deviation:

amplitude
area
base
cmean
cmedian
crms
csdev
cycles
delay
delta c2d- delta c2d+
delta delay
delta @level
duration
duty
fall
f 80-20%
f@level
first
frequency

last
maximum
mean
median
minimum
overshoot+
overshoot-
period
phase
peak-to-peak
rise
r 20-80%
r@level
rms
std dev
t@level
top
width

PASS/FAIL: Pass/Fail testing allows any five items (parameters and/or masks) to be tested against selectable thresholds. Waveform Limit Testing is performed using Masks that may be defined either inside the instrument or by downloading templates created on a PC. Any failure will cause pre-programmed actions, such as Hardcopy, Save to Internal Memory, Save to mass storage device (card or disk), GPIB SRQ, or Pulse Out.

    Company Information  |   Terms and Conditions  |   Contact Us  |   Links
Need test equipment? Test Equipment Sales located in sales tax free Londonderry,NH provides you with the latest in new and used electronic test and measurement equipment from manufacturers such as Agilent, HP, Tektronix, Instek, BK Precision, Hart Scientific, Fluke and many others. From your basic needs such as oscilloscopes and power supplies to your more complex requirements such as network analyzers and logic analyzers, Test Equipment Sales is your source. We have network analyzers and logic analyzers from such major manufacturers as Agilent, HP and Tektronix. Contact Test Equipment Sales with your test equipment needs today! Test Equipment Sales also offers Digital Phosphur Oscilloscopes (DPO), Digital Storage Oscilloscopes (DSO), analog scopes, DC Power Supplies, Multi-Output Power Supplies, Digital Multimeters, Signal Generators, Pulse/Function Generators and many other types of test and measurement equipment.

Copyright © 2009 Test Equipment Sales
Tesales and tesales.com are registered trademarks of Test Equipment Sales