Data Sheet
- Resolution 10 kHz
- Carrier Frequency 5 — 900 MHz
- Number of Carriers: 4
- Carrier Level: 30 - 50 dBmV
- Level resolution 1 dB
- Level accuracy ± 2 dB
- Impedance 75 Ω.
The RP-200 is a handheld pilot generator at direct frequency band (downstream) as well as at return band (upstream) in a CATV installation.
One of its main features, and advantages over other instruments on the market, is that the RP-200 is fully-configurable by the user, i.e. the frequency and level of each pilot can be set independently.
The RP-200 is powered by rechargeable batteries or the mains using the supplied mains adapter. The battery charger is built-in.
The RP-200 pilot generator has been designed to test cable networks and their associated devices. It generates reference signals for band equalization of both downstream and upstream channels.
The RP-200 is able to provide up to four continuous wave (CW) signals in the band from 5 to 900 MHz. This allows to test line or line sections and devices in both the forward and the return band. Using PROMAX-10 Premium or PROMAX-8 Premium in conjunction withRP-200, level differences can be adjusted with the TILT function.
Output level can be selected from 90 to 110 dBµV and independently for each carrier. The level of harmonics is -60 dB and therefore produces no interference into adjacent channels. It is an ideal equipment to install new lines and to test existing ones. The equipment is battery operated which makes it appropriate for testing trunk amplifiers.
|